workstation dealers in hyderabad, telangana, andhra pradesh
workstation latest pricelist hyderbad

numax ups

Latest numax ups models pricelist hyderabad

Numax Online Nx990 G5 10KVA 60KVA Backup UPS price hyderabad

NUMAX ONLINE NX990 G5 10KVA 60KVA BACKUP UPS

  • MODEL: Nx9910,Nx9915 Nx9920 Nx9930 Nx9940 Nx9960
  • Capacity: 10 kVA/10 kW,15 kVA/15 kW,20 kVA/20 kW,30 kVA/30 kW 40 kVA/40 kW 60 kVA/60 kW
  • INPUT:
  • Rated voltage: 380/400/415 Vac (L-L)
  • Voltage range: 304-478Vac (L-L), full load 228V-304Vac (L-L), load decrease linearly according to the min phase voltage
  • Rated frequency: 50/60 Hz (auto-sensing)
  • Frequency range: 40-70 Hz
  • Power factor: >0.99
  • Bypass voltage range: Selectable, default -20%~+15% Up limited: +10%, +15%, +20%, +25%; Down limited: -10%, 15%, -20%, -30%, -40%
  • Bypass frequency range: Selectable, ±1Hz, ±3Hz, ±5Hz
  • Total harmonic distortion (THDI): <3% (full linear load)
  • Bypass overload: 125%: long term operation; 125%~130%: 10min; 130%~150%: 1min; 150%-400%: 1s; >400%, less than 200ms
  • OUTPUT:
  • Rated voltage: 380/400/415 Vac (L-L)
  • Voltage regulation: ±1% (full linear load)
  • Frequency: Synchronized with utility in mains mode, 50/60 Hz ±0.1% in battery mode
  • Waveform: Sinusoidal
  • Power factor: 1
  • Total harmonic distortion (THDv): <1% (full linear load) <3% (full non-linear load according to IEC/EN62040-3)
  • Crest factor: 3:1
  • Overload: <110%, 60min; 110%~125%, 10min; 125%~150%, 1min; >150%, 200ms
  • BATTERIES:
  • DC voltage: Long time model: ±240VDC (Selectable, 32-40pcs)
  • Inbuilt battery (standard model): (10 + 10) * 9AH ( (20 + 20) * 7AH ( 20+20)* 9AH x 2 strings (15 + 15) * 9AH (20+20) x 9AH x 2 strings
  • Charging current: 10A Max. 15A Max. 20A Max.
  • Charger voltage precision: 1%
  • Recharge time.: Standard model: 90% capacity restored in 8 hours; Long time model: depend on the capacity of battery
  • SYSTEM:
  • Efficiency: 95% Max
  • Transfer time Max. number of parallel connections: 0 ms
  • Max. number of parallel connections: 4
  • Protections: Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
  • Communications: RS232, USB, RS485, EPO, Dry contacts, Parallel port (Standard) SNMP card, WI-FI card, GPRS card, SMS alarms (Optional)
  • Display: LED + 5 inches LCD touch screen
  • OTHERS:
  • Operating temperature: 0^ C sim 40 deg * C
  • Storage temperature: 40 deg * C - 70 deg * C
  • Relative humidity: 0-95% (Non-condensing)
  • Altitude: <1000m, load derated 1% per 100m from 1000-2000m
  • IP rating: IP 20
  • Noise level at 1 m:55dB @ 100% load, 52dB @ 50% load 58dB @ 100% load, 55dB @ 50% load
  • Dimensions (WDH) (mm): 250 * 720 * 560 ( ) 250 * 720 * 560 (H) 250 * 800 * 700(S) 250 * 720 * 560(H) 250 * 800 * 700(S) 250 * 720 * 560(H)
  • Packaged dimensions (WDH) (mm): 350 * 800 *722 (s)350 * 800 * 718(H).(350 * 900 * 862(S) 350 * 800 * 718(H) 350*950*1102 (S)350*980*810(H)
  • Net weight (kg): 82 (S) 31 (H),131 (S) 33 (H),145 (S) 33 (H),215 (S) 42 (H)
  • Gross weight (kg): 93 (S) 40 (H) 142 (S) 42 (H) 156 (S) 42 (H) 227 (S) 52 (H)
Numax Online Nx900 G5 10KVA 20KVA Backup UPS price hyderabad

NUMAX ONLINE NX900 G5 10KVA 20KVA BACKUP UPS

  • MODEL: Nx9010 (3:1),Nx9015 (3:1),Nx9020(3:1)
  • Capacity: 10 kVA/10 kW,15 kVA/15 kW,20 kVA/20 KW
  • INPUT:
  • Input wiring: Three-phase five-wire (3 + N + PE)
  • Rated voltage: 380/400/415 Vac
  • Voltage range: 380/400/415 Vac
  • Rated frequency: 50/60 Hz (auto-sensing)
  • Frequency range: 40-70 Hz
  • Power factor: ? 0.99
  • Bypass voltage range: -40%~+15% (settable)
  • Total harmonic distortion (THDI): 5%
  • OUTPUT:
  • Output wiring: Single-phase three-wire (10 + N + ??)
  • Rated voltage: 208 (PF=0.9)/220/230/240 Vac
  • Voltage regulation: ±1%
  • Frequency: Synchronized to bypass in mains mode; 50/60 Hz ± 0.1% Hz in battery mode
  • Waveform: Sinusoidal
  • Power factor: 1
  • Total harmonic distortion (THDv): 1% (linear load); 3% (non-linear load)
  • Crest factor: 3:1
  • Overload: 105%~110% for 10 min, 110% 125% for 1 min, 126%~150% for 30 s
  • BATTERIES:
  • DC voltage: 120 Vdc (120-240 Vdc settable)
  • Number of battery: 10 pcs (10-20 settable)
  • Inbuilt battery (standard model): 12 V/9Ah×10
  • Charging current: Standard model: 1 A; Long time model: 5 A (default), 1-5A settable; 10 A (optional)
  • Recharge time: Standard model: 90% capacity restored in 8 hours; Long time model: depend on the capacity of battery
  • SYSTEM:
  • Efficiency: 94% at 100% load, max. 95% at 60% load, 98% in ECO mode
  • Transfer time: 0 ms
  • Protections: Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure.
  • Max. number of parallel connections: 4
  • Communications: RS232 (standard), USB/RS485/dry contacts/SNMP / battery temperature compensation (optional)
  • Display: LCD + LED
  • OTHERS:
  • Operating temperature: 0^ C sim 40 deg * C
  • Storage temperature: -25^ C sim 55 deg * C (without battery)
  • Relative humidity: 0 sim 95% non-condensing)
  • Altitude: <= 1000m , derating 1% for each additional 100 m
  • IP rating: IP 20 / IP 21
  • Noise level at 1 m: 58 dB
  • Dimensions (WDH)(mm): 191 * 495 * 711(S) 191 * 495 * 350(H),191 * 495 * 515 (t )
  • Packaged dimensions. (WDH) (mm): 310 * 685 * 941(S) 318 * 617 * 475(H),285 * 593 * 618(H)
  • Net weight (kg): 64 (S), 18.5 (H),26.5 (H)
  • Gross weight (kg): 72 (S), 20 (H),28 (H)
Numax Online Nx890 B 80KVA 600KVA Backup UPS price hyderabad

NUMAX ONLINE NX890 B 80KVA 600KVA BACKUP UPS

  • MODEL: Nx8980 | Nx89100| Nx89120 | Nx89120 |Nx89200 | Nx89250 | Nx89300 | Nx89400 | Nx89500 | Nx89600
  • Capacity: 80 kVA | 100KVA | 120KVA | 160KVA | 200KVA | 250KVA | 300KVA | 400KVA | 500KVA | 600KVA |
  • INPUT:
  • Input wiring: Three-phase five-wire (30+N+PE)
  • Rated voltage: 380/400/415 Vac
  • Voltage range: 304346 V (derating 10%), 346~456 V (full load)
  • Rated Frequency: 50/60 Hz
  • Frequency range: (50/60) ±5 Hz
  • Power factor: 20,99
  • Total harmonic distortion (THDI): 3%
  • Delayed start of rectifier: 10 s (1300 settable)
  • Bypass voltage range: ± 20% (settable)
  • OUTPUT:
  • Output wiring: Three-phase five-wire (3Ø+N+PE)
  • Rated voltage: 380/400/415 Vac
  • Output Voltage regulation: ±1%
  • Output Frequency regulation: 50/60 Hz ± 0.1% Hz in battery mode
  • Waveform: Sinusoidal
  • Power factor: 0.9/0.8
  • Voltage distortion (THDV): 2% (linear load); 5% (non-linear load)
  • Crest Factor: 3:1
  • Overload: 105% 110% for 60 min, 110%~125% for 10 min
  • BATTERIES:
  • DC Voltage: Lead acid battery: 600 Vdc Lithium iron phosphate battery: 614.4 Vdc
  • Number of battery: Lead Acid battery: 12 V x 50 pcs (support 48~52 pcs) Lead Acid battery: 2 V x 300 pcs (support 288~312 pcs) Lithium iron phosphate battery: 3.2 V x 192 pcs (support 192/208 pcs)
  • Charging current: Charging rate (settable) x battery capacity (settable) x number of battery groups (settable)
  • SYSTEM:
  • Efficiency: Line mode 92% ECO mode 97%,Line mode 94% ECO mode 98%
  • Max. number of parallel connections: 6
  • Protections: Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure.
  • Communications: Standard configuration: RS232, RS485, dry contacts Optional configuration: SNMP card, temperature compensation, SMS alarms
  • Display: 5.7 inches LCD touch screen
  • OTHERS:
  • Operating temperature: 0^ C sim 40 deg * C
  • Storage temperature: -25^ C sim 55 deg * C (without batteries)
  • Relative humidity: 0% sim95\% non-condensing)
  • Altitude: 1000 m, Above 1000 m, derating 1% for each additional 100 m
  • IP rating: IP 20
  • Noise level at 1 m: 65 dB
  • Dimensions (WxDxH) (mm): 800 * 800 * 1800,800 * 860 * 860* 1700,,1210 * 860 * 1950,2380*860*1950
  • Dimensions (WxDxH) (mm): 900 * 900 * 2050,900 x 1000 x 1950,1300 * 1000 * 2200,1300 * 1000 * 2200 (*2)
  • Net weight (kg): 580,630,680,790 1135,1275,1355,2090,2300
  • Gross weight (kg): 630 680 730 840,1200,1340,1420,2200,2410
Numax Nx890 A 10KVA 120KVA Online Backup UPS price hyderabad

NUMAX NX890 A 10KVA 120KVA ONLINE BACKUP UPS

  • MODEL: Nx8910 | Nx8915 | Nx8920 | Nx8930 | Nx8940 | Nx8960 | Nx8980 | Nx89100 | Nx89120
  • Capacity:10 kVA | 15 kVA | 20 kVA | 30 kVA | 40 KVA | 60 KVA | 80 kVA | 100 kVA | 120 kVA
  • INPUT:
  • Input wirting:Three-phase five-wire (30+N+PE)
  • Rated voltage: 380/400/415 Vac
  • Voltage range: 285-475 V
  • Frequency range: (50/60) ± 5 Hz
  • Power factor:  0.95 (with Filter)
  • Delayed start of rectifier:10 s (1-300 settable)
  • Bypass voltage range: ±20% (settable)
  • OUTPUT:
  • Output wiring: Three-phase five-wire (30+ N + PE)
  • Rated voltage: 380/400/415 Vac
  • Output Voltage regulation: ±1%
  • Output Frequency: 50/60 Hz ± 0.1% Hz in battery mode
  • Waveform: Sinusoidal
  • Power factor: 0.9/0.8
  • Voltage distortion (THDv): 1% (linear load); 5% (non-linear load)
  • Crest Factor: 3:1
  • Overload: 105%~110% for 60 min, 110% 125% for 10 min
  • BATTERIES:
  • DC Voltage: Lead acid battery: 360 Vdc Lithium iron phosphate battery: 384 Vdc
  • Number of battery: Lead Acid battery: 12 V x 30 pcs (support 28-32 pcs) Lead Acid battery: 2 V x 180 pcs (support 168-192 pcs) Lithium iron phosphate battery: 3.2 V x 120 pcs (support 112/120 pcs)
  • Charging current: Charging rate (settable) x battery capacity (settable) x number of battery groups (settable)
  • SYSTEM:
  • Efficiency: In Line mode: Max, 93%; ECO mode: 98%
  • Max. number of parallel connections: 6
  • Protections: Short-circuit, overload, over temperature, battery low voltage, over voltage, under voltage and fan failure
  • Communications: RS232/RS485/dry contacts (standard), SNMP (optional)
  • EMI: EN62040-2
  • EMS: IEC61000-4-2 (ESD) IEC61000-4-3 (RS) IEC61000-4-4-(EFT) IEC61000-4-5 (surge)
  • OTHERS:
  • Operating temperature: 0^ C sim 40 deg * C
  • Storage temperature: -25^ C sim 55 deg * C (without batteries)
  • Relative humidty: 0%-95% (non-condensing)
  • Altitude: 1000 m (derating 1% for each additional 100m)
  • IP rating: IP 20
  • Noise level at 1 m: 65 dB
  • Dimensions(WxDxH) (mm): 400 * 800 * 1100 , 600 * 700 * 1500,700 * 800 * 700
  • Packaged dimensions (WxDxH) (mm): 490 * 920 * 1300,700 x 800 x 1650,800 * 900 * 1850
  • Net weight (kg): 158 165 175 210 260 460 590 630 690
  • Gross weight (kg): 200 207 217 252 302 480 620 660 720
Numax Online Nx800 10KVA 30KVA Backup UPS price hyderabad

NUMAX ONLINE NX800 10KVA 30KVA BACKUP UPS

  • MODEL: Nx810 (3:1) Nx815 (3:1) Nx820 (3:1),Nx830 (3:1)
  • Capacity: 10 kVA/8 kW 15 kVA/20 KVA/30 kVA/24 kW
  • INPUT:
  • Input wiring: Three-phase five-wire (30+N+PE)
  • Rated voltage: 380/400/415 Vac
  • Voltage range:285-475 Vac
  • Rated frequency: 50/60 Hz
  • Frequency range: 40-70 Hz
  • Bypass voltage range: ± 25% (settable)
  • OUTPUT:
  • Output wiring: Single-phase three-wire (10+ N + PE)
  • Rated voltage: 220/230/240 Vac
  • Output voltage regulation: ± 1%
  • Rated frequency: 50/60 Hz (settable)
  • Output frequency regulation: 50/60 Hz ± 0.1 Hz in battery mode
  • Waveform: Sinusoidal
  • Power factor: 0.8
  • Voltage distortion (THD): <2% (linear load): ?5% (non-linear load)
  • Crest factor: 3:1
  • Overload: 105%~125% for 10 min, 125%-150% for 1 min, 150%-200% for 200 ms, > 200% for 100 ms.
  • BATTERIES:
  • DC voltage: 192 Vdc
  • Number of batteries: 12 V x 16 pcs
  • Charging voltage: 216 Vdc
  • EOD: 168 Vdc
  • Charging current: Default 8 A (2A/4A/6A/8A/10A/12 A selectable)
  • SYSTEM:
  • Max. number of parallel connections.: 2
  • Protections: Short-circuit, overload, overvoltage, undervoltage, low battery, overtemperature
  • Communications: RS232/USB (standard); RS485/SNMP/dry contacts (optional)
  • OTHERS:
  • Operating temperature: 0 sim 40 deg * C
  • Storage temperature: -25?~55? (without batteries)
  • Relative humidity: 0~95% (non-condensing)
  • Altitude: <1000 m (derating 1% for each additional 100 m)
  • IP rating: IP 20
  • Noise level at 1 m.: < 60 dB
  • Dimensions (WxDxH) (mm): 310 * 600 * 880 400 * 815 * 1100
  • Packaged dimensions 430 * 710 * 1080 525 * 925 * 1305 (WDH) mm): 430 * 710 * 1080 525 * 925 * 1305
  • Net weight (kg): 430 * 710 * 1080 525 * 925 * 1305
  • Gross weight (kg): 153 225 255 295
Numax Online 990 G5 10KVA 60KVA Backup UPS price hyderabad

NUMAX ONLINE 990 G5 10KVA 60KVA BACKUP UPS

  • Brand: Numax
  • MODEL: Nx9910 Nx9915 Nx9920 Nx9930
  • Capacity: 10kVA/10kW 15kVA/15kW 20kVA/20kW 30kVA/30kW
  • INPUT:
  • Rated voltage: 380 / 400 / 415 Vac (3 + N + PE)
  • Voltage range: 304~478Vac, full load 228 V ~ 304 Vac, load decrease linearly according to the min phase voltage
  • Rated frequency: 50 / 60 Hz (auto-sensing)
  • Frequency range: 40 ~ 70 Hz
  • Power factor: > 0.99
  • Bypass voltage range: Selectable, default -20%?+15% Up limited: +10%, +15%, +20%, +25%; Down limited: -10%, -15%, -20%, -30%, -40%
  • Bypass frequency range: Selectable, ±1Hz, ±3Hz, ±5Hz
  • Total harmonic distortion (THDi): <3% (full linear load)
  • Bypass overload: 125%: Long term operation; 125%~130%: 10min; 130%~150%: 1min; 150%~400%: 1s; >400%, less than 200ms
  • OUTPUT:
  • Rated voltage: 380 / 400 / 415 Vac (3 + N + PE)
  • Voltage regulation: ±1% (full linear load)
  • Frequency: Synchronized with utility in mains mode, 50 / 60Hz ±0.1% in battery mode
  • Waveform: Sinusoidal
  • Power factor: 1
  • Total harmonic distortion (THDv): <1% (full linear load); <3% (full non-linear load according to IEC/EN62040-3)
  • Crest factor: 3:1
  • Overload: <110%, 60min; 110%~125%,10min; 125%~150%,1min; >150%, 200ms
  • BATTERIES:
  • DC voltage: ±240VDC(selectable, 32 - 40pcs)
  • Charging current: 10 A max 15A 20A
  • Charger voltage precision: 1%
  • Recharge time: Long time model: depend on the capacity of battery
  • SYSTEM:
  • Efficiency: 95% Max 96% Max
  • Transfer time: 0 ms
  • Max. number of parallel connections: 4
  • Protections: Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
  • Communications: Sandard: RS232, USB, RS485, EPO, Dry contacts, Parallel port Optional: SNMP card, WI-FI card, GPRS card, SMS alarms
  • Display: LED + 5 inches LCD touch screen
  • OTHERS:
  • Operating temperature: 0 ~ 40
  • Storage temperature: -40~70
  • Relative humidity: 0  95% (non-condensing)
  • Altitude: <1000m, load derated 1% per 100m from 1000 2000m
  • IP rating: IP 20
  • Noise level at 1m: <60dB <65dB
  • Dimensions (W × D × H) (mm): 440*660*130 440*750*130 440*730*130 440*800*130
  • Packaged dimensions (W × D × H) (mm): 532*800*204 532*890*204 535*865*226 535*930*226
  • Net weight (kg): 22 24 29 33 39
  • Gross weight (kg): 24 26 31 36 42
Numax Online NX900RT G4 10 20KVA Backup UPS price hyderabad

NUMAX ONLINE NX900RT G4 10 20KVA BACKUP UPS

  • Brand: Numax
  • MODEL: NX9010RT (3:1) NX9015RT (3:1) NX9020RT (3:1)
  • Capacity: 10 kVA / 10 kW 15 kVA / 15 kW 20 kVA / 20 kW
  • INPUT:
  • Input wiring: Three-phase five-wire (3 + N + PE)
  • Rated voltage: 380 / 400 / 415 Vac
  • Voltage range: 190 ~ 304 Vac (linear derating between 50% and 100% load); 304 ~ 478 Vac (no derating)
  • Rated frequency: 50/60Hz(auto-sensing)
  • Frequency range: 40 ~ 70 Hz
  • Power factor: 0.99
  • Bypass voltage range: - 40% ~ +15% (settable)
  • Total harmonic distortion (THDI): 5%
  • OUTPUT:
  • Output wiring: Single-phase (L-N)
  • Rated voltage: 208 (PF=0.9) / 220 / 230 / 240 Vac
  • Voltage regulation: ±1%
  • Frequency: Synchronized to bypass in mains mode; 50 / 60 Hz ± 0.1% Hz in battery mode
  • Waveform: Sinusoidal
  • Power factor: 1
  • Total harmonic distortion (THDV): 1% (linear load); 3% (non-linear load)
  • Crest factor: 3:1
  • Overload: 105% ~ 110% for 10 min, 110% ~ 125% for 1 min,125% ~ 150% for 30 s
  • BATTERIES:
  • DC voltage: 192 Vdc (192 ~ 240 Vdc settable)
  • Number of battery: 16 pcs (16 ~ 20 settable)
  • Inbuilt battery (standard model): 12 V / 9 Ah × 16
  • Charging current: Standard model: 1 A; Long time model: 5 A (default),1 ~ 5 A settable; 10 A (optional)
  • Recharge time: Standard model: 90% capacity restored in 8 hours; Long time model: depend on the capacity of battery
  • SYSTEM:
  • Efficiency: 94% at 100% load, max. 95% at 60% load, 98% in ECO mode
  • Transfer time: 0 ms
  • Protections: Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
  • Max. number of parallel connections: 4
  • Communications: RS232 (standard), USB / RS485 / dry contacts / SNMP / battery temperature compensation (optional)
  • Display: LCD + LED
  • OTHERS:
  • Operating temperature: 0 ~ 40
  • Storage temperature: -25 ~ 55 (without battery)
  • Relative humidity: 0 ~ 95% (non-condensing)
  • Altitude: 1000 m, derating 1% for each additional 100 m
  • IP rating: IP 20
  • Noise level at 1 m: 58 dB
  • Dimensions (W × D × H) (mm): 440 × 650 × 88 (H) 440 × 660 × 176 (S) 440 ×780 × 132
  • Packaged dimensions (W × D × H) (mm): 514 x 696 x 168 (H) 554 x 792 x 418 (S) 554 x 792 x 400
  • Net weight (kg): 17 (H), 67 (S) 25.5
  • Gross weight (kg): 19 (H), 77 (S) 28
Numax NX900RT G4 5KVA 10KVA Online Backup UPS price hyderabad

NUMAX NX900RT G4 5KVA 10KVA ONLINE BACKUP UPS

  • Brand: Numax
  • MODEL: NX905RT / NX906RT /NX910RT
  • Capacity: 5kVA / 5KW / 6kVA / 6KW / 10 kVA / 10 KW
  • INPUT:
  • Input wiring: Single-phase three-wire (1 + N + PE)
  • Rated voltage: 208 / 220 / 230 / 240 Vac
  • Voltage range: 110 ~ 176 Vac (linear derating between 50% and 100% load); 176 ~ 288 Vac (no derating)
  • Rated frequency: 50 / 60 Hz (auto-sensing)
  • Frequency range: 40 ~ 70 Hz
  • Power factor: 0.99
  • Bypass voltage range: - 40% ~ +15% (settable
  • Total harmonic distortion (THDI): 5%
  • OUTPUT:
  • Output wiring: Single-phase (L-N)
  • Rated voltage: 08 (PF=0.9) / 220 / 230 / 240 Vac
  • Voltage regulation: ± 1%
  • Frequency: Synchronized to bypass in mains mode; 50 / 60 Hz ± 0.1% Hz in battery mode
  • Waveform: Sinusoidal
  • Power factor: 1
  • Total harmonic distortion (THDV): ? 1% (linear load); 4% (non-linear load)
  • Crest factor: 3:1
  • Overload: 105% ~ 110% for 10 min, 110% ~ 125% for 1 min,126% ~ 150% for 30 s
  • BATTERIES:
  • DC voltage: 192 Vdc (192 ~ 240 Vdc settable)
  • Number of battery: 16 pcs (16 ~ 20 settable)
  • Inbuilt battery (standard model): 12 V / 7 Ah × 16 12 V / 9 Ah × 16
  • Charging current: Standard model: 1 A; Long time model: 5 A (default),1 ~ 5 A settable; 12 A (optional)
  • Recharge time: Standard model: 90% capacity restored in 8 hours; Long time model: depend on the capacity of battery
  • SYSTEM:
  • Efficiency: 94% at 100% load, max. 94.5% at 60% load, 98% in ECO mode
  • Transfer time: 0 ms
  • Protections: Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
  • Max. number of parallel connections: 4
  • Communications: RS232 (standard), USB / RS485 / dry contacts / SNMP / battery temperature compensation (optional)
  • Display: LCD + LED
  • OTHERS:
  • Operating temperature: Operating temperature 0 ~ 40
  • Storage temperature: -25 ~ 55 (without battery)
  • Relative humidity: 0 ~ 95% (non-condensing)
  • Altitude: 1000 m, derating 1% for each additional 100 m
  • IP rating: IP 20
  • Noise level at 1 m: 55 dB 58 dB
  • Dimensions (W × D × H) (mm): 440 × 580 × 88 (H), 440 × 660 × 176(S)
  • Packaged dimensions (W × D × H) (mm): 514 x 696 x 168 (H), 554 x 792 x 418 (S)
  • Net weight (kg): 12 (H), 58 (S) 14 (H), 63 (S)
  • Gross weight (kg): 14 (H), 68 (S) 16 (H), 73 (S)
Numax DOU Series RT G4 1KVA 3KVA Backup UPS price hyderabad

NUMAX DOU SERIES RT G4 1KVA 3KVA BACKUP UPS

  • Brand: Numax
  • MODEL: DOU1KRT DOU2KRT DOU3KR
  • Capacity: 1 kVA / 1 kW 2 kVA / 2 kW 3 kVA / 3kW
  • INPUT:
  • Rated voltage: 208 / 220 / 230 / 240 Vac
  • Voltage range: 110 ~ 176 Vac (linear derating between 50% and 100% load ); 176 ~ 280 Vac (no derating); 280 ~ 300 Vac (derating 50%)
  • Frequency range: 50/60 Hz ± 5 Hz (auto-sensing)
  • Power factor: 0.99
  • Bypass voltage range: - 40% ~ +20% (settable)
  • THDi:  5%
  • OUTPUT:
  • Voltage: 208 / 220 / 230 / 240 Vac (settable via LCD)
  • Voltage regulation: ± 1%
  • Frequency: 45~55Hz or 55~65Hz(synchronized range); 50/60Hz ±0.1Hz?battery mode)
  • Waveform: Sinusoidal
  • THDv:  2% (linear load), 5% (non-linear load)
  • Crest factor: 3:1
  • Overload: 105% ~ 110% for 30 min, 110% ~ 130% for 10 min, 130% ~ 150% for 30 s, > 150% for 500 ms
  • BATTERIES:
  • Battery type: Sealed lead acid maintenance free battery
  • DC voltage: 24V(S) 36V(S) 24V(H) 36V(H) 48V(S) 72V(S) 48V(H) 72V(H) 72V(S) 96V(S) 72V(H) 96V(H)
  • Inbuilt battery: 2×9Ah 3×7Ah / / 4×9Ah 6×7Ah / / 6×9Ah 8×7Ah
  • Charging current (max.): Standard model: 1 A Long time model: 12 A (1 ~12A settable)
  • Recharge time: Standard model: 90% capacity restored in 3 hours; Long time model: depend on the capacity of battery
  • SYSTEM CONTROL AND COMMUNICATIONS:
  • Efficiency:
  • 93.5% (Mains mode)  94.5% (Mains mode) 94.4% (Mains mode)
  • 89.2% (Battery mode) 91% (Battery mode) 92.3% (Battery mode)
  • 97.5% (ECO mode) 98.5% (ECO mode) 98.3% (ECO mode)
  • Transfer time: Mains mode to battery mode: 0 ms Inverter mode to bypass mode: 4 ms (typical)
  • Protections: Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection
  • Communication port: RS232 (standard), USB / RS485 / SNMP/ dry contacts (optional)
  • Display: LCD + LED
Numax DOU Series 1KVA 10KVA Backup UPS price hyderabad

NUMAX DOU SERIES 1KVA 10KVA BACKUP UPS

  • Brand: Numax
  • Model: DOU1K DOU2K DOU3K DOU5K DOU6K DOU10K
  • Capacity: 1kVA/kW 2kVA/kW 3kVW/kW 5kVA/kW 6kVA/kW 10KVA/KW
  • Nominal Voltage: 220/230/240 VAC (1ph+N+ PE, 3wire)
  • Operating Voltage range: 110V-300V AC @ 50% Load/140V-300VAC @ Full Load
  • Operating Frequency range: 50/60 Hz ± 10% (Auto Sensing)
  • Power factor: >0.99
  • OUTPUT:
  • Output Voltage/Power factor: 220/230/240 Vac/ ± 1%/1 Unity Pf
  • Output frequency: Auto sensing 50/60 Hz ±1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery mode
  • linear load): ? 5% (non-linear load): 2% (linear load): 5% (non-linear load)
  • Crest factor: 3:1
  • Efficiency: Up to 94% Dual Conversion Mode, 99% ECO mode
  • Waveform: Sinusoidal
  • BATTERY:
  • DC voltage: 36V 48V 72V 96V 72V Sinusoidal 96V 120-240V Configurable
  • Charger: 6.5-13A Configurable
  • Typical Recharge Time: 8-12 Hours (90% of full capacity)
  • SYSTEM FEATURES:
  • LCD Indications: Input Voltage/Frequency, Output Voltage/Frequency, Battery Voltage, Load Watt/VA and %, Inverter Temperature, Operation Mode such as "On Line", "ON Batt" or On "Bypass", Fault Codes, Battery & Load Bar graph, Input Current, Output Current, Battery current
  • LED Indications: Normal Operation, Bypass, Abnormal, Fault and Battery Mode
  • Alarms/Protection: Batt. Low, DC High, Inverter Under/Over Voltage, UPS over Load, Short Circuit, Fan Failure and UPS fault, Transient surge, Input & Output Fuse
  • Overload Capability: 125% for 10 min, 125-150% for 1 min, 150% for 200ms
  • Transfer Time: AC to Battery: Oms, Inverter to Bypass: 4ms (Typical)
  • ENVIRONMENTAL:
  • Temperature: Operating: 0-45°C, Storage:-10°C-55°C
  • Humidity/Altitude: 0-95% RH (non-condensing)/<1500M
  • Noise/Cooling: <55 Db/Forced air Cooling
  • PHYSICAL:
  • Dimensions (W x D x H) (mm): ( 144x400x215 A Net weight (kg) STANDARDS Quality Safety/ IP Rating 192x469x399 6 10.7 10.8 11.2 10.8 11.2 EMC/Performance COMMUNICATION INTERFACE Standard Optional ISO 9001:2015, ISO 140001:2015, BIS IEC/EN62040-1/IP20/Ip21 IEC/EN62040-2; IEC/EN62040-3, Complying to CE RS-232 SNMP/ModBus/Dry Contact/USB/RS-485 220x481x438
  • Net weight (kg) STANDARDS: 6 10.7 10.8 11.2 1017 18 20.8 11.2
  • STANDARDS:
  • Quality: ISO 9001:2015, ISO 140001:2015, BIS
  • Safety/ IP Rating: IEC/EN62040-1/IP20/Ip21
  • EMC/Performance: IEC/EN62040-2; IEC/EN62040-3, Complying to CE
  • COMMUNICATION INTERFACE:
  • Standard: RS-232
  • Optional: SNMP/ModBus / Dry Contact/USB/RS-485
  • Monitoring Software: iStars v2.0 / NetAgent utility v5.8/UPSilon 2000

NUMAX UPS Dealers in Hyderabad, Telangana, Andhra pradesh

At our store, we offer a comprehensive selection of premium servers, workstations, and IT components to power your business efficiently. Our diverse product range is designed to meet the evolving technology needs of businesses across all sectors.

With a strong presence in Chennai and Hyderabad, we proudly serve businesses of all sizes across India. Whether you're setting up a new IT infrastructure or upgrading existing systems, we provide reliable solutions tailored to your needs. From enterprise-grade rack, tower, and blade servers to high-performance workstations, we have the technology to handle even the most demanding workloads.

We go beyond being just an IT hardware provider. we aim to be your trusted partner in success. Our mission is to help you unlock your business’s full potential through cutting-edge technology and expert support. Whether it’s a powerful graphics card for creative applications or a dependable RAID card for advanced data protection, we have you covered.

SEARCH TAGS

Workstation design, workstation table, hp z840 workstation price in india, hp workstation z840, workstation desktop, workstation furniture, dell precision 7000, examples of workstation computers, dell workstation india, workstation computer configuration, hp workstation india, dell precision tower 3620 price in india, workstation vs desktop, workstation laptop price in india, dell precision india, workstation for office, lenovo workstation india, workstation dell, types of workstation, fujitsu computing, precision 5820 tower, information appliances, precision 7920 tower, precision t5810, define technological convergence, workstation synonym, standalone workstation, fujitsu workstation price in india, dell workstation, workstation computer price, workstation desktop, workstation price, workstation computer configuration, workstation hp, workstation computer specifications, Workstation price, Workstations india, Workstation models, Workstation pricelist, Workstation dealers, Workstation Dealers in Hyderabad, Workstation price in Hyderabad, Workstation retailers in Hyderabad, Workstation suppliers in Hyderabad, hp Workstation dealers in Hyderabad, hp Workstation dealers in telangana, hp Workstation dealers in andhra pradhesh, dell Workstation dealers in Hyderabad, dell Workstation dealers in telangana, dell Workstation dealers in andhra pradesh, lenovo Workstation dealers in Hyderabad, lenovo Workstation dealers in telangana, lenovo Workstation dealers in andhra pradesh, Workstation dealers in hyderabad, Workstation dealers in telangana, Workstation dealers in andhra pradesh, Workstation price india, Workstation brands, HP Workstation price, Dell Workstation price, IBM Workstation price, Cisco Workstation price - Workstations India, Workstation Hyderabad, Type of Workstations, Workstation Price, Workstations list, Workstation dealers, Workstation models, dell Workstations, hp Workstations, ibm Workstations, lenovo Workstations, cisco Workstations, mrs rack Workstations, acer Workstations, Workstation price list, branded Workstations, Workstation accessories, Workstation ram, Workstation processor, Workstation graphics cards, Workstation memory, Workstation accessories, Workstation support

For Sale & Supply of Goods

we offering all brand Servers, Storages, Firewall, Tape Drivers, Networking, Switches, Workstations, Desktops, Thinclients, NComputing, Laptops, Surfaces, Tabs, Plotters, Printers & Scanners, Copier machines, LFD Monitors, Projectors & Screens, Soundstations, Audio & Video conferencings, CCTV Camera, UPS, Carepacks, Tonners & Catridges, Batteries & Adapters, Softwares, etc.

Server & Workstation goods supply in Telangana & andhra pradesh

Anantapur (Dharmavaram, Gooty, Guntakal, Hindupur, Kadiri, Kalyandurg, Rayadurg, Tadpatri), Chittoor(Madanapalle, Punganur, Palamaner, Nagari, Srikalahasti, Puttur), East Godavari (Amalapuram, Mandapeta, Peddapuram, Pithapuram, Yeleswaram, Ramachandrapuram, Samalkot, Tuni), Guntur (Bapatla, Chilakaluripet, Macherla, Mangalagiri, Narasaraopet, Piduguralla, Ponnur, Repalle, Sattenapalle, Tadepalle, Tenali, Vinukonda), Kadapa (Badvel, Mydukur, Proddatur, Pulivendula, Rayachoti, Jammalamadugu, Rajampet, Yerraguntla), Krishna (Gudivada, Jaggaiahpet, Nuzvid, Pedana, Tiruvuru) Kurnool (Adoni, Nandikotkur, Nandyal, Yemmiganur, Dhone, Guder, Allagadda, Atmakur), Nellore (Atmakur, Gudur, Kavali, Sullurpeta, Venkatagiri, Naidupeta), Prakasam (Chirala, Kandukur, Markapur), Srikakulam (Amudalavalasa, Ichchapuram, Palasa-Kasibugga), Visakhapatnam (Narsipatnam, Yelamanchili), Vizianagaram (Bobbili, Parvathipuram, Salur), West Godavari (Bhimavaram, Kovvur, Narasapuram, Nidadavole, Palakollu, Tadepalligudem, Tanuku), Hyderabad, Warangal, Nizamabad, Khammam, Karimnagar, Ramagundam, Mahabubnagar, Nalgonda, Adilabad, Suryapet, Miryalaguda, Siddipet, Peddapalli, Nalgonda